| AC Current range |
42.00 to 1000 A, 3 ranges
(40 Hz to 1 kHz, True RMS),
Basic accuracy: ±1.5 % rdg. ±5 dgt. |
| DC Voltage range |
420.0 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. |
| AC Voltage range |
4.200 V to 600 V, 4 ranges
(45 to 500 Hz, True RMS),
Basic accuracy: ±1.8 % rdg. ±7 dgt. |
| Crest factor |
2.5 or less at 2500 counts
(Linearly decreases to 1.5 or less at 4200 count) |
| Resistance range |
420.0 Ω to 42.00 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt. |
| Other functions |
Continuity: Buzzer sounds at 50 Ω ±40 Ω or less, Data hold, Auto power save, Drop-proof from height of 1 meter |
| Display |
LCD, max. 4199 dgt., Display refresh rate: 400 ms |
| Power supply |
Coin type lithium battery (CR2032) ×1
Continuous use 70 hours |
| Core jaw dia. |
φ 33 mm (1.30 in) |
| Dimensions and mass |
57 mm (2.24 in) W × 181 mm (7.13 in) H × 16 mm (0.63 in) D, 100 g (3.5 oz) |
| Included accessories |
CARRYING CASE 9398 × 1, TEST LEAD L9208 × 1, Coin type lithium battery (CR2032) × 1, Instruction manual × 1 |